Ircam-Centre Pompidou

Recherche

  • Recherche simple
  • Recherche avancée

    Panier électronique

    Votre panier ne contient aucune notice

    Connexion à la base

  • Identification
    (Identifiez-vous pour accéder aux fonctions de mise à jour. Utilisez votre login-password de courrier électronique)

    Entrepôt OAI-PMH

  • Soumettre une requête

    Consulter la notice détailléeConsulter la notice détaillée
    Version complète en ligneVersion complète en ligne
    Version complète en ligne accessible uniquement depuis l'IrcamVersion complète en ligne accessible uniquement depuis l'Ircam
    Ajouter la notice au panierAjouter la notice au panier
    Retirer la notice du panierRetirer la notice du panier

  • English version
    (full translation not yet available)
  • Liste complète des articles

  • Consultation des notices


    Vue détaillée Vue Refer Vue Labintel Vue BibTeX  

    %0 Conference Proceedings
    %A Susini, Patrick
    %A Maffiolo, Valérie
    %T Loudness evaluation of urban soundscapes by a cross-modal matching method
    %D 1999
    %B ASA & FORUM ACUSTICUM joint meeting
    %C Berlin
    %F Susini99b
    %K cross-modal matching method
    %K urban soundscapes
    %K discriminable sources
    %X In a previous study, loudness of a time-varying pure tone was evaluated using a cross-modal matching method. In this procedure, the loudness was matched to an equivalent muscular force. Subjects had to judge the instantaneous and global loudness using a proprioceptive input device with force feedback. Using this technique subjects could respond easly, rapidly, continuously, and with feedback concerning their evaluation. The present study examines the relation between instantaneous and global loudness of sixteen urban soundscapes lasting about 20 s using the same method. First, the procedure is individually calibrated with 1-s soundscapes presented at different sound pressure levels. The data obtained for each subject fit well with a linear relation on log-log scale between the sound pressure level in dB and the associated force in log Newtons. Then, the global judgments are performed under two experimental conditions: one with instantaneous loudness evaluation during stimulus presentation and one without. Good correlation was found between these two judgments. The global judgment and the average over the instantaneous matching contour are nearly identical. In addition, a fluction factor (FI) calculated on the loudness judgment contour reflects the degree of movement produced by the subject as well as the presence of discriminable sources.
    %1 7
    %2 3

    © Ircam - Centre Pompidou 2005.